TYN1100 Series solar inverter
- Product Details
- Company Profile
Item No.: TYN1100 6kva-30kva PV1:180VDC~350VDC PV2:180VDC~350VDC Frequency: 50Hz/60Hz5% Battery Voltage: 360Vdc ( 2V battery 180pcs in serial or 12V battery 30pcs in serial ) Payment terms: T/T, L/C, Western Union Lead time: 18 days Warranty: 1 year
TYN1100 Series solar inverter
TYN1100 Series Brief
TYN1100 series solar inverter is a single phase inverter, which range from 6KVA to 30KVA, This inverter is a multifunctional intelligent power supply, which consists of MPPT solar controller, charger, rectifier, inverter, static transfer switch, main control circuit and display alarming circuit. It can set different inverter work mode according to users’ actual application.
Two Work Mode
1. PV---Grid---Battery: This series solar inverter is designed for real-time sharing function between solar power and utility power. Solar power priority, solar power supply power to inverter via MPPT controller, and then output pure sine wave AC power to load via inverter, meanwhile charge battery. When solar power is not enough, the utility power will supply power to load. In this way, we can maximum use solar power and utility power, reduce battery discharge time and extend battery lifespan.
2. PV-Battery-Grid ( Maximum use solar power under the stable environment of utility power ): Solar power supply power to inverter via MPPT controller, and then output pure sine wave AC power to load via inverter, meanwhile charge battery. When the solar power is not enough, to maximum use solar power, the battery will supply power to load. When the battery is discharged to a value, the utility power will supply power to load. The users can maximum use solar power, reduce grid power supply and save electricity.
Feature:
1.High efficiency IGBT (Insulated Gate Bipolar Transistor)inverter technology: the 6th generation IGBT has the nature of lower saturation voltage drop, higher efficiency of inverter, lower heat, more reliable.
2.Instinctive LED status display, work status can be seen at a glance by workflow indicator.
3.Perfect protection function: Input-output over-low voltage protection, input surge protection, phase protection, battery overcharge-over discharge protection, output overload shortcut protection, overheat protection and alerting.
4.Two charging mode: AC charging mode and solar charging mode, solar charging priority. Can choose AC charging current 0A-3A-6A by panel switch
5.Can choose two work mode: Solar-Grid-Battery, Solar –battery-Grid, Can choose it by LCD screen
6.Solar power & Grid power priority (when battery voltage is 11.2v, low voltage and power off), Under no grid power, solar power is normal, it can automatic restart the inverter (single cell voltage 12.5v automatic restart)
7.Intelligent communicate: With RS232 and RS485 standard collocation, optional SNMP and dry contact.
8.Optional built-in Input & output electric meter: the meter can show the Input & output power Instinctively.
9.Selectable battery inspection module - Can test the single parameter and display on the LCD, battery failure will immediately alarm and inform the administrator.
Parameters:
Model | TYN1106K | TYN1110K | TYN1115K | TYN1120K | TYN1130K |
Capacity (KVA) | 6kVA | 10kVA | 15kVA | 20kVA | 30kVA |
Power ( Watts ) | 4.8kW | 8kW | 12kW | 16kW | 24kW |
Grid (AC Input) | |||||
Max input current (A) | 37 | 61 | 91 | 121 | 181 |
Type | Single Phase ( P+N+PE ), 220VAC | ||||
Input voltage | 220/230/240VAC±25% | ||||
Input frequency | 220/230/240VAC±25% (100/110/120VAC is optional) | ||||
Charge voltage | 219V±1% | ||||
Charge current | 0-3A-6A, Can adjust through panel switch | ||||
PV | |||||
PV1 | 180VDC~350VDC ( 8pcs 24vdc solar panel in series,then through combiner box parallel ) | ||||
PV2 | 180VDC~350VDC ( single group 8pcs 24vdc solar panel in series, or through combiner 2 pcs in parallel ) | ||||
Charge current | 20A ( max ) | ||||
Battery | |||||
Type | Maintenance free lead-acid battery (other type battery need customize ) | ||||
Battery voltage | 192Vdc( 2V battery 96pcs in serial or 12V battery 16pcs in serial ) | ||||
Battery capacity | According to backup time | ||||
Battery low voltage protection | >172.8V | ||||
Inverter (Output) | |||||
Inverter outputwaveform | Pure sine wave, THD<3% (linear load) | ||||
Inverter voltage | 220/230/240VAC±1%(stable load), 220/230/240VAC±5% (load fluctuation), (100/110/120VAC is optional) | ||||
Frequency | 50/60Hz±0.5% | ||||
Dynamic feature | Inverter output transient dynamic range less than±5%,recovery time <20mS | ||||
Crest factor | 3:1 | ||||
Overload protection | (Inverter output)125% overload, delay 1mins protect, 150% overload, immediate protect | ||||
Inverter efficiency | >90% ( 100% load ) | ||||
System Parameters | |||||
Transfer time | <0.5ms ( inverter--bypass ) | ||||
Protection | Output short circuit, overload, overvoltage, under voltage, over temperature etc protection, have audible and visual alarm | ||||
Display | LCD display input and output voltage, output current, the inverter voltage, frequency, output current, battery voltage, PV voltage, PV charging current, temperature mode, flowcharts, current work status, event record and system information | ||||
Operating environment | Temperature 0-40℃ | ||||
Relative humidity | 30%-95% | ||||
Work sequence | Solar-Grid-Battery or Solar –battery-Grid, Can choose one of the mode via LCD panel | ||||
Operation altitude ( max) | <1000 meters ( per increase 100 meters power decrease 1%, at most 4000 meters ) | ||||
Computer communicate interface | RS232/RS485 | ||||
Cooling method | force-air cooling | ||||
Size W×D×H (unit: mm) | 300*570*850 | 350*600*850 | |||
Weight (kg) | 108 | 146 | 162 | 178 | 195 |