MP3100 Series 3/1 phase online ups
- Product Details
- Company Profile
Input: 380/400/415/200/208/220VAC±25% Output: 380/400/415/200/208/220VAC Frequency: 50Hz , 60Hz Battery Voltage: 360VDC Payment terms: T/T or L/C or Western Union Lead time: 18~20 days Warranty: 2 years
MP3100 series Brief
MP3100 series on-line intelligent digital UPS agglomerates the essence of Baykee techniques and entirely break through the bottleneck technology in traditional simulation circuit age. It is to adopt the digital control technology, of which the core is high-speed MCU and programmable logic device (CPLD). It brings in the sixth generation low-exhaust and big-power IGBT module and static switch as power devices.It is really the highlights product which was guided by these most advanced technologies all over the world.
High-precision SMD technology to ensure higher precision machine.
digital control technology, fully intelligent digitization.
Barrier free man-machine conversation
Full digital and intelligent
Advanced digital circuit system
Intelligent battery management
Intelligent detection system
ntelligent communication tool
High reliability
The sixth generation IGBT
High speed static switch
High-precision SMD technology
Perfect protection
User-friendly
humanization great LCD screen
Intuitive LED status indicators
MP3100 Series 3/1 phase online ups parameters
MODEL | MP3106K | MP3110K | MP3115K | MP3120K | MP3125K | MP3103K |
Capacity | 6kVA | 10kVA | 15kVA | 20kVA | 25kVA | 30kVA |
Power Watt | 4.8kW | 8kW | 12kW | 16kW | 20kW | 24kW |
Working Principle | Low Freuqency Transformer Based True On Line-Double Conversion | |||||
RECTIFIER (INPUT) | ||||||
Phase | Three Phase | |||||
Input Power Factor | Standard > 0.9 ( 6pulse Rectifier+Filter ), Optional >0.96 ( 12pulse Rectifier+Filter) | |||||
Input Voltage Range | 220/380VAC (230V/400VAC or 240V/415VAC)±25% 3P+N+PE 110V/208V (120V/220V or 277V/480VAC) | |||||
Input Frequency Range | 50Hz±10% / 60Hz±10% (Selectable) | |||||
Output Ripple | <2% | |||||
Soft Start | 0~100% 5sec | |||||
CHARGING | ||||||
Charging Mode | Constant current, then constant voltage, and charge with temperature compensation, automatic switch Between Equalized charging and Float charging | |||||
Float Charging Voltage | 405VDC | |||||
Equalized Charging Voltage | 432VDC | |||||
Temp. Compensated Voltage | -3mV/℃/cell | |||||
Charging Current | 0.1C ( Automatic adjust according to battery capacity) | |||||
BATTERY | ||||||
Type | VRLA/AGM/Gel, optional Lithium Battery | |||||
Battery Capacity | 7~999AH settable ( Choose Battery Capacity according to Back-up Time ) | |||||
Quantity | 30units 12V or 180units 2V batteries (Nominal Voltage 360VDC) | |||||
Temperature | 20ºC~25ºC (For Maximum Efficiency) | |||||
INVERTER (OUTPUT) | ||||||
Phase | Single Phase | |||||
Rated Voltage | Rated Capacity*0.9 | |||||
Nominal Voltage | 220VAC (230VAC or 240VAC), 1P + N optional 110V(120V or 277V ) | |||||
Output Voltage Regulated Accuracy | ±1 %( Stable load), ±3%( fluctuant load) | |||||
Output Frequency Range | 50Hz 60Hz<±0.5% ( Asynchronous ) | |||||
Crest Factor | > 3:1 | |||||
Output Total Harmonic Distortion (THD) | Pure Sine Wave, Linear Load < 3%, Non-Linear Load<5% | |||||
Dynamic Characteristics | Instant voltage<±5% ( from 0 to100% ), Instant recover time<10ms | |||||
Unbalanced Load Voltage | < ± 5% | |||||
Overload Capacity | At 115% load, normal work, At 125% load 10 min, At 150% load 1min, At 200% load 1S | |||||
Inverter Efficiency | >93% ( full load ) | |||||
BYPASS | ||||||
Phase | Single Phase | |||||
By-pass Input Voltage | 220/380VAC (230V/400VAC or 240V/415VAC) optional 110V(120V or 277V ) | |||||
By-pass Output Voltage | 220VAC (230VAC or 240VAC) optional 110V(120V or 277V ) | |||||
Transfer Time | 0ms( adopt static switch ) | |||||
PROTECTION FUNCTION | ||||||
Input Protection | Input voltage, frequency over limited protection, Phase fault, Phase lack | |||||
Output Protection | Over current, short circuit, over voltage, low voltage | |||||
Battery Protection | Over charge, over-discharge protection | |||||
Temperature Protection | Environment over temperature protection, inverter over temperature protection | |||||
Hardware Fault Protection | Assistant power abnormal, breaker cut off, breaker overload, power devices over current/over voltage etc protection | |||||
GENERAL SYSTEM PARAMETERS | ||||||
Working Environment | Temp: -10~40ºC, relative humidity: 30%~90%, Altitude<2000m ( 1% decrease against 100 meters’ rise, max. altitude 4000m ) | |||||
Cooling Method | COMPULSIVE VENTILATION | |||||
Communitation Interface | RS232/ RS485, optional dry contact, SNMP card ( for remote control via internet ) | |||||
Parallel Operation | Tandem hot backup or parallel connection | |||||
Auti-surge Capacity | 10/700μS, 5KV; 8/20μS, 20KA | |||||
Protection Level | IP21 | |||||
Safety Performance | Vin-n Vout-n 2000Vac, creepage<10mA , insulating resistance>2MΩ(500VDC) | |||||
Noise (dB) | 45~50 | 50~55 | 55~58 | |||
Dimension (W*D*H) mm | 450*600*1200 | |||||
Weight (Kg) | 65 | 168 | 183 | 210 | 241 | 246 |