EVI Air to Water Heat Pump Overview This air source heat pump is using Scroll EVI Copeland compressor, and EVI technology to make strong capacity to heating when cold ambient, a digital controller to feel and defrost. EVI air source heat pump 12kW 19kW to pass EN14825 ERP energy level test, all SCOP: A+, and passed TUV CE certificate. We using monobloc design to easy install, and high-efficiency heat exchanger, inside directly building high pressure, low pressure sensor to easily read and balance inside safe pressure. One key touch controller auto running connect 16PCS heat pump by modular, can control by Mobile phone or computer from Connect R485S port on the PCB panel.
Domestic Hot Water Heat Pump Overview
Heating Capacity Range: 8kW/12kW/15kW/18kW for buyer to choose,
220V/1Ph/50Hz power supply suit for home Heating & Cooling,
by Inverter technology this domestic water heat pump can directly working -20℃ in winter,
produce max 50℃ hot water for heating room, summer produce 7℃ for cooling water.
DC inverter EVI heat pump --Heating in Winter + Cooling in Summer | |||||||
Model | RSV-8A/C | RSV-12A/C | RSV-15A/C | RSV-18A/C | RSV-20A/SC | ||
HP | 3P | 5P | 6P | 8HP | 9HP | ||
Power supply | V/Hz | 220V/50Hz | 380V/50Hz | ||||
Heating (air+7℃/water35℃) | Rated heating capacity | kW | 9.5 | 14.5 | 17.8 | 20.0 | 22.4 |
Rated heating input power | kW | 2.2 | 3.4 | 4.1 | 4.6 | 5.7 | |
Rated current | A | 10.2 | 15.8 | 19.0 | 21.3 | 9.6 | |
COP | w/w | 4.3 | 4.3 | 4.3 | 4.3 | 3.9 | |
Heating (air+2℃/water35℃) | Rated heating capacity | kW | 9.5 | 14.5 | 17.5 | 19.5 | 22.4 |
Rated heating input power | kW | 2.4 | 3.6 | 4.4 | 4.9 | 6.2 | |
Rated current | A | 11.1 | 16.7 | 20.4 | 22.7 | 10.4 | |
COP | w/w | 4.0 | 4.0 | 4.0 | 4.0 | 3.6 | |
Heating (air-7℃/water35℃) | Rated heating capacity | kW | 7.5 | 11.5 | 13.8 | 15.2 | 17.5 |
Rated heating input power | kW | 2.5 | 3.7 | 4.4 | 4.9 | 5.8 | |
Rated current | A | 11.6 | 17.2 | 20.4 | 22.7 | 9.8 | |
COP | w/w | 3.0 | 3.1 | 3.1 | 3.1 | 3.0 | |
Heating (air+2℃/water45℃) | Rated heating capacity | kW | 9.5 | 14.5 | 17.5 | 19.5 | 22.2 |
Rated heating input power | kW | 3.0 | 4.4 | 5.3 | 5.9 | 7.2 | |
Rated current | A | 13.9 | 20.4 | 24.6 | 27.4 | 12.1 | |
COP | w/w | 3.2 | 3.3 | 3.3 | 3.3 | 3.1 | |
Heating (air-7℃/water45℃) | Rated heating capacity | kW | 7.5 | 11.5 | 13.8 | 15.2 | 17.0 |
Rated heating input power | kW | 2.9 | 4.2 | 5.2 | 5.8 | 6.6 | |
Rated current | A | 13.5 | 19.5 | 24.1 | 26.9 | 11.1 | |
COP | w/w | 2.6 | 2.7 | 2.7 | 2.6 | 2.6 | |
Cooling (air35℃/water7℃) | Rated cooling capacity | kW | 7.5 | 12.0 | 14.4 | 17.2 | 20.0 |
Rated cooling input power | kW | 2.7 | 4.0 | 4.8 | 6.0 | 7.1 | |
Rated current | A | 12.5 | 18.6 | 22.3 | 27.8 | 12.0 | |
EER | w/w | 2.8 | 3.0 | 3.0 | 2.9 | 2.8 | |
Circulating water flow volume | m3/h | 1.3 | 2.1 | 2.5 | 3.0 |