Portable EV Charger Station
- Product Details
- Company Profile
The new high-efficiency three-phase PFC circuit topology is adopted, the power factor is greater than 0.99, and the harmonic distortion rate is ≤5%. The high-frequency switching power supply module adopts full-bridge phase-shift soft-switching technology, and the execution efficiency is high. The advanced digital current sharing technology effectively improves the current sharing accuracy and anti-interference; the first module sleep technology and the wheeling technology ensure the high-efficiency operation of the system; Intelligent charging process control and perfect charging process monitoring and protection, fool-like operation; One button is automatically filled with simple and practical; Display the charging voltage, current, SOC and other information and operating status in real time, and display the charging degree after charging is completed; Module hot swap technology makes maintenance more convenient;
Overview
The new high-efficiency three-phase PFC circuit topology is adopted, the power factor is greater than 0.99, and the harmonic distortion rate is ≤5%.
The high-frequency switching power supply module adopts full-bridge phase-shift soft-switching technology, and the execution efficiency is high.
The advanced digital current sharing technology effectively improves the current sharing accuracy and anti-interference; the first module sleep technology and the wheeling technology ensure the high-efficiency operation of the system;
Intelligent charging process control and perfect charging process monitoring and protection, fool-like operation;
One button is automatically filled with simple and practical;
Display the charging voltage, current, SOC and other information and operating status in real time, and display the charging degree after charging is completed;
Module hot swap technology makes maintenance more convenient;
Working environment temperature -20+50 °C.
Scope of application
Portable DC charging piles for private use (private cars, logistics vehicles, trucks, etc.)
The operating company leases with the car.
The yard is delivered with the car;
Particularly suitable for rapid deployment where the site is limited.
The main technical parameters
Product number | KECP-DC-7KW | KYCP-DC-15KW | KYCP-DC-20KW | |
Detailed specifications | rated power | 7KW | 15KW | 20KW |
Charging equipment | User Interface | Digital tube, LED | ||
Installation method | Portable | |||
Way of routing | After going in and out | |||
Equipment size | 345*175*265 | 540*375*195 | 540*375*195 | |
Input voltage | AC220V±20% | AC380V±20% | AC380V±20% | |
Input frequency | 45~65Hz | |||
Charging equipment | The output voltage | 200V-450V | 200V-750V | |
Single gun output current range | 0-15A | 0-20A | ||
The output voltage | 250V-750V | 200V-750V(constant power) | 200V-750V | |
Single gun output current range | 0-11A | 0-37.5A | 0-37.5A | |
Cable length | 5m (gun line 2m) | |||
Measurement accuracy | Level 0.5 | |||
Current limit protection value | ≥110% | |||
Voltage regulation accuracy | ≤±0.5% | |||
Steady flow accuracy | ≤±1% | |||
Ripple coefficient | ≤±0.5% | |||
effectiveness | ≥94.5% | |||
Power factor | ≥0.99 (50% load or more) | |||
Harmonic content THD | ≤5% (50% load or more) | |||
HMI | LED indicator | |||
Charging mode | Automatic charging | |||
payment method | no | |||
Communication Interface | no | |||
Executive standard | GB\T 20234, GB/T 18487, GB/T 27930, NB\T 33008 | |||
security function | Overvoltage protection, undervoltage protection, overload protection, short circuit protection, grounding protection, over temperature protection, low temperature protection, leakage protection | |||
Operating temperature | -25°C~+50°C | |||
Working humidity | 5%~95% non-condensing cream | |||
Working elevation | <3000m | |||
Protection level | IP20 | |||
cooling method | Air cooled | |||
Noise control | ≤55dB | |||
MTBF | 100,000 hours |
parameter | Min | Type | Max | Unit | Remarks |
range of working temperature | -40 | 25 | 85 | ℃ | Intelligent derating of shell temperature over 70 °C |
Operating humidity range | 20 | 25 | 95 | RH% | No condensation |
Altitude | 2000 | m | |||
Atmospheric pressure | 70 | 106 | Kpa | ||
Heat dissipation method | Air cooled |
Installation environment requirements
Ensure that the input yellow PE line is grounded reliably;
It is forbidden to use in an environment with rain;
Keep away from flammable, explosive and corrosive sources;
Avoid steam and dust;
Keep away from electromagnetic interference sources;
Keep away from the heat source and fully consider the space around the pile to facilitate heat dissipation.