Atomic Absorption Spectrometer
- Product Details
- Company Profile
• With the latest nuclear embedding technique to automatic control and data processing, to ensure reliability • High performance liquid screen, to indicate parameters and measuring data • Auto adjust negative high voltage and lamp current • Auto transfer spectral bandwidth, 0.1nm, 0.2nm, 1.0nm, 2.0nmnm for option • Auto control wavelength scanning, auto seeking, all band fast scanning and positioning in 30 seconds • Auto zeroing could deduct zero drift of the influence to the data • Auto energy adjustment • Comprehensive gas leakage protection warning device • The best flame height and atomizer position for option, to choose the best analysis condition • Adjustable gas flow to select the best combustion supporting ratio of the element analysis • Hydride generator for option • The excellent quality of the optical system, optical system suspension design, the vibration and the environmental temperature changes can not affect the instrument performance The basic parameters of AAS-2600 could be accordance with the basic parameters of the atomic absorption spectrophotometer in GB/T21187-2007 professional standard.
Features
· With the latest nuclear embedding technique to automatic control and data processing, to ensure reliability
· High performance liquid screen, to indicate parameters and measuring data
· Auto adjust negative high voltage and lamp current
· Auto transfer spectral bandwidth, 0.1nm, 0.2nm, 1.0nm, 2.0nmnm for option
· Auto control wavelength scanning, auto seeking, all band fast scanning and positioning in 30 seconds
· Auto zeroing could deduct zero drift of the influence to the data
· Auto energy adjustment
· Comprehensive gas leakage protection warning device
· The best flame height and atomizer position for option, to choose the best analysis condition
· Adjustable gas flow to select the best combustion supporting ratio of the element analysis
· Hydride generator for option
· The excellent quality of the optical system, optical system suspension design, the vibration and the environmental temperature changes can not affect the instrument performance
The basic parameters of AAS-2600 could be accordance with the basic parameters of the atomic absorption spectrophotometer in GB/T21187-2007 professional standard.
Performance Index
Optical system
· Wavelength: 190nm-900nm
· Monochromator: C-T, aberration
· Spectrum bandwidth: 0.2nm, 0.4nm, 1.0nm, 2.0nm for option
· Wavelength accuracy: ±0.25nm
· Wavelength repeatability: 015nm
· Baseline shift: ±0.004A/30min
· Detector: photomultiplier
Atomic system
· Sensitivity: concentration 3.0μg/ml, absorbance >0.300Abs
· (Cu) detection limit: 0.006μg/ml
· Burner: 100mm titanium metal, air premixed
· Precision: RSD≤1%
· Sprayer: high efficiency glass atomizer
· Atomizing chamber: corrosion resistant material
· Position adjustment: flame burner optimum height, front and rear position adjustable, complete the transfer between the flame and the hydride in one minute
· Safety: with many kinds of automatic protection, acetylene gas leakage alarm, closed system
Analytic method
· Measurement method: air-acetylene flame method, hydride generator atomic absorption method
· Concentration calculation: standard curve method (1-3 times curve), auto fitting, standard addition method
· Repetition survey frequency: 1-20times, calculate average value, ,display standard deviation and relative standard deviation
· Printing result: parameters print, data result print
·
Instrument Parameter
· Source: AC 220V/50HZ
· Power: 150VA
· Weight: 70Kg
· Volume: 1000mm (L)×350mm(W)×390mm(H)
· Operating temperature: 15℃~30℃
· Operating humidity: ≤75%
Standard Layout
· Main host
· Low noise oil free air compressor
· Accessories
· Installation and commissioning
· Wooden case packaging and transportation