Earth-leakage Vigi Add-on Protection Module For CNSX
- Product Details
- Company Profile
With 30 years experience, we produce quality product with moderate price. Looking for dealer, wholesaler and other type of clients for further cooperation.
CNSX Vigi add-on
Addition of the Vigi add-on does not modify circuit-breaker characteristics:
compliance with standards
degree of protection, class II front-face insulation
positive contact indication
electrical characteristics
trip-unit characteristics
installation and connection modes
indication, measurement and control auxiliaries
installation and connection accessories.
Picture | Rated Voltage | Model | Dimension(mm) | Weight(kg) |
220-440V 440-550V | CNSX、CNSV、CNS 100-250A 3P | 105*236*86 | 2.5 | |
CNSX、CNSV、CNS、CEZC 400-630A 3P | 135*355*110 | 8.8 | ||
CNSX、CNSV、CNS 100-250A 4P | 140*236*86 | 3.2 | ||
CNSX、CNSV、CNS、CEZC 400-630A 4P | 180*355*110 | 10.8 |
Remote indications
Vigi add-on may be equipped with an auxiliary contact (SDV) to remotely signal tripping due to an earth fault.
Use of 4-pole Vigi add-on with a 3-pole CNSX
In a 3-phase installation with an uninterrupted neutral, an accessory makes it possible to use a 4-pole Vigi add-on with connection of the neutral cable.
Power supply
Vigi add-on are self-powered internally by the distribution-system voltage and therefore do not require any external source. They continue to function even when supplied by only two phases.
Vigi add-on selection | |||
Type | Vigi ME | Vigi MH | Vigi MB |
Number of poles | 3,4 | 3,4 | 3,4 |
CNSX 100 | √ | √ | × |
CNSX 160 | √ | √ | × |
CNSX 250 | × | √ | × |
CNSX 400 | × | × | √ |
CNSX 630 | × | × | √ |
A Sensitivity setting
B Time-delay setting (for selective earth-leakage protection).
C Lead-seal fixture for controlled access to settings.
D Test button simulating an earth-fault for regular checks on the tripping function
E Reset button (reset required after earth-fault tripping).
F Rating plate
G Housing for SDV auxiliary contact.
Protection characteristics | |||
Sensitivity | fixed | adjustable | adjustable |
In (A) | 0.3 | 0.03-0.3-1-3-10 | 0.3-1-3-10-30 |
Time delay | fixed | adjustable | adjustable |
Intentional delay (ms) | <40 | 0-60-150-310 | 0-60-150-310 |
Max. break time (ms) | <40 | <40<140<300<800 | <40<140<300<800 |
Rated voltage V AC 50/60 Hz | 200...440 | 200...440-440...550 | 200...440-440...550 |
Vigi 3P add-on may also be used on 3P circuit breakers used for two-phase protection.
If the sensitivity is set to 30 mA, there is no time delay, whatever the time-delay setting.
Operating safety
The Vigi add-on is a user safety device. It must be tested at regular intervals (every 6 months) via test button.