3/3 Three Phase Low Frequency Online Transformer Base UPS Power Supply for 60-600KVA
- Product Details
- Company Profile
1.IGBT inverter and output isolation transformer 2.Manual maintenance bypass switch 3.Wide input voltage range 4.RS232/RS485/dry contact communication port 5.SNMP adapter (optional) 6.Fully DSP control and high reliability and performance 7.3 phase UPS allow 100% unbalanced load 8.EPO function(optional) 9.7 inches touchable LCD screen
3B3GX 60K-600K
Main feature
1.IGBT inverter and output isolation transformer
2.Manual maintenance bypass switch
3.Wide input voltage range
4.RS232/RS485/dry contact communication port
5.SNMP adapter (optional)
6.Fully DSP control and high reliability and performance
7.3 phase UPS allow 100% unbalanced load
8.EPO function(optional)
9.7 inches touchable LCD screen
Application
1.Data center
2.Industrial equipment
3.Commercial facility
4.Telecom system
5.Medical/bank system
6.Precision instrument
Specification
Model | 3B3 GX 60K | 3B3 GX 80K | 3B3 GX 100K | 3B3 GX 120K | 3B3 GX 160K | 3B3 GX 200K | 3B3 GX 250K | 3B3 GX 300K | 3B3 GX 400K | 3B3 GX 500K | 3B3 GX 600K |
Capacity | 60 kVA | 80 kVA | 100 kVA | 120 kVA | 160 kVA | 200 kVA
| 250 kVA
| 300 kVA
| 400 kVA
| 500 kVA
| 600 kVA
|
Input features | |||||||||||
Pulse rectifier | 6 pulse | 6/12 pulse | 12 pulse | ||||||||
Voltage range(Vac) | 380/400/415Vac±15%(±25%) | ||||||||||
Frequency range(HZ) | 40—70Hz Automatically select synchronization range according to grid frequency | ||||||||||
Phase | 3φ4W+PE | ||||||||||
Battery voltage(Vdc) | 384 | ||||||||||
Battery quantity(Pcs) |
30-34 can be adjusted | 30-34 can be adjusted | |||||||||
Output features | |||||||||||
Power Factor | 0.8/0.9 | ||||||||||
Voltage(V) | L-N:220/230/240±1% L—L:380/400/415±1% | ||||||||||
Frequency(HZ) | Mains normal,track mains frequency;Mains abnormal,50±0.2% | ||||||||||
Transfer time(ms) | 0 | ||||||||||
Efficiency(AC mode @ full loads) | ≥92% | ||||||||||
Parallel function |
Yes(for optional) | ||||||||||
Waveform | Linear Load THD<3%;Non-linear Load THD<5% | ||||||||||
Overload | 125% load keep 10 min,150% load keep1min | ||||||||||
Peak Factor | >3:1 | ||||||||||
Others | |||||||||||
Manual maintenance bypass |
with no transfer time bypass maintenance switch | ||||||||||
Communication function | RS232 / RS485/dry contact | ||||||||||
SNMP(optional) | Can be network monitored by SNMP adapter | ||||||||||
Noise (dB) | <65(within 1 meter) | ||||||||||
Alarm | Battery low-voltage, mains abnormal, overload, UPS fault, over temperature protection | ||||||||||
Protection | Input over-voltage protection, battery under-voltage protection, overload protection, short circuit protection, over temperature protection | ||||||||||
Cooling way | Forced cooling | ||||||||||
Working Temperature(℃) |
0~40 | ||||||||||
Humidity | 0~95%,No Condensing | ||||||||||
Size(D×W×H) (mm) |
800*800*1600(6 pulse)/1100*800*1800(12 pulse) |
1100*800*1800 |
1405*1113*2005 | 1605*1113*2005 | 2600*1100*2000 | ||||||
Weight(T) | 0.48 | 0.56 | 0.89 | 1.08 | 1.28 | 1.38 | 1.68 | 1.98 | 2.48 | 2.85 | 3.15 |
Note: