Low Frequency Double Conversion Online Transformer Base UPS Power Supply for 1-20kVA
- Product Details
- Company Profile
1.IGBT inverter and output isolation transformer 2.Online double conversion 3.Wide input voltage range 4.RS232 communication port 5.SNMP +USB+dry contact(optional) 6.High reliability and performance 7.External battery pack (optional)
B1kVA-20kVA
Main feature
1.IGBT inverter and output isolation transformer
2.Online double conversion
3.Wide input voltage range
4.RS232 communication port
5.SNMP +USB+dry contact(optional)
6.High reliability and performance
7.External battery pack (optional)
Application
1.Data center
2.Industry
3.Commercial facility
4.Telecom system
5.Precision instrument
Specification
Model | B1K S/L | B2K S/L | B3K S/L | B4K S/L | B6K S/L | B10K S/L | B15K | B20K | |
Capacity | 1KVA | 2KVA | 3KVA | 4KVA | 6KVA | 10KVA | 15KVA | 20KVA | |
Input features | |||||||||
Input voltage(Vac) |
165~275 | ||||||||
Frequency(HZ) | 45~66 Automatically select synchronization range according to grid frequency | ||||||||
Phase | Single phase three wires | ||||||||
Battery voltage(Vdc) |
48 |
96 |
96/192 |
192 | |||||
Battery type |
4*7Ah 12V/External
|
8*7Ah 12V/External
| 8/16*7Ah 12V/External
|
16*7Ah 12V/External |
External | ||||
Output features | |||||||||
Power factor | 0.8/0.9 | ||||||||
Voltage(V) | 220/230/240±1% | ||||||||
Frequency(HZ) | 50/60±0.5%(Free oscillation) | ||||||||
Transfer Time(ms) | 0 | ||||||||
Waveform | Sine Wave,THD<3% | ||||||||
Overload Capacity | 110%~129% full load keep 10min;130%~150% load keep 60s; | ||||||||
Others | |||||||||
Crest Factor | >3:1 | ||||||||
Parallel function | No | Yes(for optional) | |||||||
Backup time | Standard time is 10min/ Long backup time can be extended freely | ||||||||
Charge recovery time |
<10hours | ||||||||
Communication | RS232(USB/dry contact are optional) | ||||||||
SNMP(Optional) |
Can be network monitored by SNMP adapter | ||||||||
Display | LED display work status and fault indicator;LCD display single phase input voltage, input frequency, single phase output voltage, load, battery voltage etc | ||||||||
Noise (dB) | <60(within 1 meter) | ||||||||
Alarm | Battery low-voltage, mains abnormal, overload, UPS fault, over temperature protection | ||||||||
Protection | Input over-voltage protection, battery under voltage protection, overload protection, short circuit protection, over temperature protection | ||||||||
Working temperature(℃) |
0~40 | ||||||||
Humidity | 0~95%,No Condensing | ||||||||
Size(D×W×H) (mm) |
590*230*717(S)/590*230*540(L)
|
596*305*1065/890 |
700*405*955 | ||||||
Weight(KG) | 80/50 | 99/60 | 107 /52 | 113 /58 | 115 /60 | 160/ 116 | 127 | 195 |
Note:
1、“L” is long backup UPS,“S” is standard UPS;
2、Because the products are continuously improved, please contact the company or dealer to inquiry the latest specification.