air source heat pump for hot water and space heating
Recommended by CCCME
- Product Details
- Company Profile
air source heat pump for hot water and space heating
air source heat pump for hot water and space heating
Warm series(Air source heat pump for Hot water & Space heating) | |||||||
FH03Ps-S5 | FH05Ps-S5 | FH03P-S5 | FH05P-S5 | FH07P-S5 | |||
EXW USD/unit | $1,220.00 | $1,540.00 | $1,230.00 | $1,540.00 | $1,830.00 | ||
Hot water heating capacity | kW | 11.6 | 18.6 | 11.7 | 18.7 | 24.3 | |
Input power for hot water heating | kW | 2.80 | 4.42 | 2.83 | 4.43 | 5.82 | |
Input current for hot water heating | A | 14.92 | 23.63 | 5.38 | 8.41 | 11.05 | |
Hot water performance coefficient(COP) | / | 4.14 | 4.21 | 4.13 | 4.22 | 4.18 | |
Space heating capacity | kW | 8.7 | 13.5 | 8.8 | 13.7 | 18.2 | |
Input power for space heating | kW | 2.70 | 4.23 | 2.71 | 4.30 | 5.62 | |
Input current for space heating | A | 13.64 | 21.34 | 5.16 | 8.53 | 11.45 | |
Heating performance coefficient(COP) | / | 3.22 | 3.19 | 3.25 | 3.19 | 3.24 | |
Maximum input power | kW | 3.43 | 5.52 | 3.39 | 5.53 | 7.72 | |
Maximum input current | A | 18.07 | 29.05 | 6.40 | 10.46 | 14.58 | |
Rated hot water output temp. | ℃ | 55 | |||||
Rated output temperature of space heating | ℃ | 45 | |||||
Max. hot water output temp. | ℃ | 60 | |||||
Rated hot water produce capacity | L/h | 258.0 | 408.5 | 258.0 | 408.5 | 537.5 | |
Power supply | 1N 220V~240V/50Hz | 3N 380V~420V/50Hz | |||||
Compressor | Type | Heremetic scroll type | |||||
Start mode | Directly start(Soft start) | ||||||
Water side heat exchanger | Type | Shell and coil heat exchanger | |||||
Water flow | m3/h | 2.1 | 3.3 | 2.1 | 3.3 | 4.3 | |
Water pressure drop | kPa | ≤40 | ≤40 | ≤40 | ≤40 | ≤40 | |
Pipe size | DN | DN20 | DN25 | DN20 | DN25 | ||
Protections | 1. High pressure and low pressure protection, 2. Anti-freezing protection, 3. High temperature protection, 4. Too big of the water temperature difference for outlet and inlet protection, 5. Overload protection, 6. Lack phase protection, 7. Reverse phase protection, etc.. | ||||||
Refrigerant | Type | R410A | |||||
Throttle type | Electronic expansion valve | ||||||
Quantity(kg) | 1.9 | 2.8 | 1.9 | 2.8 | 4.2 | ||
Noise | DB(A) | ≤60 | ≤63 | ≤60 | ≤63 | ≤65 | |
Unit dimensions | Length | mm | 835 | 835 | 835 | 835 | 835 |
Width | mm | 433 | 433 | 433 | 433 | 433 | |
Height | mm | 1328 | 1328 | 1328 | 1328 | 1328 | |
Weight | kg | 100 | 160 | 100 | 160 | 180 | |
1. Hot water standard condition: Initial water temperature 15 ℃, the setting water temperature 55 ℃; Dry-bulb temperature 20℃, wet bulb temperature 15℃. | |||||||
2. Heating standard condition: Dry-bulb temperature 7℃, wet bulb temperature 6℃; Cold water inlet temperature 40℃, Hot water outlet temperature 45℃; | |||||||
The above parameters based on Refrigearnt R410A, for parameters based on other refrigerants please contact us. | |||||||
The above parameters may have some differences from the final product because of products updating, so above information is not the provision of any business contract. Please refer to final product label when buy, or refer to us for any information. Our company keeps the right to interpret. | |||||||