ZH-YX3232-32 Channels Input and Output IO Port Control Module
- Product Details
- Company Profile
ZH-YX3232-32 Channels Input and Output IO Port Control Module
This product adopts 32-bit ARM processor, its DI and DO using high-speed magnetic isolation and optocoupler isolation technology. And also it uses RS232&RS485 or network port, so the communication protocol is optional----standard Modbus-RTU and Modbus-TCP protocol, which can be networked with PLC, configuration software, text display, etc.
Furthermore, with 32 channels of relay outputs, 32 channels of switch status acquisition, the product has functions, such as voltage or current acquisition optional, voltage or current output, PWM control, etc. The communication circuit adopts lightning protection and anti-interference design, which can be widely used in signal control of industrial field equipment.
Features
Optional functions including AI, AO, PWM output.
Each channel of the MAX 32 channels IO has a maximum switching current of 5A and a maximum switching power of 1385VA/150W, with high-speed magnetic isolation, strong anti-interference, stable performance and high reliability;
The switch input uses photoelectric isolation, which can be connected to dry and wet nodes such as key switch, relay output, magnetic/proximity switch, infrared switch, active signal input, etc. For active input signal, it can be powered separately from the main power supply and effectively isolated;
Abundant status indicators, including switch output status indicator, switch input status indicator, communication indicator, power indicator, etc.;
One-key initialization: press Init-SET, then power on to reset, and after 5 seconds, the system will restore to factory settings;
With standard isolation RS232, RS485 interface, customizable network port 100M/10M TCPIP interface, CAN interface;
Built-in TTL communication port, which is used to expand communication modules such as GSM/ GRPS/ CDMA/ ZigBee/ Wi-Fi/ Bluetooth;
Various relay output modes can be set through the protocol;
Built-in alarm buzzer, which can remotely control the alarm and remind the scene;
Built-in 8-bit DIP switch, various functions can be flexibly set according to the following table:
DIP switch bit | Functions | Details |
No.8 | Linkage setting | Set ON, there is DI and corresponding DO; The output is linked with the input |
No.7 | Communication loss reset | Set ON, the communication is lost for 2 seconds, and the output of all relays is turned off |
No.6 | Device address settings | Set ON, use software to set the device address; Set OFF, the switch sets the device address mode; The 5th to 1st bits of the switch correspond to the set device address (No. 1-31, coded according to 8421) |
No.5--1 | Switches 5-4 OFF, 1 ON | The communication address is 1 |
Switches 5-3/1 OFF, 2 ON | The communication address is 2 | |
Switches 5-3 OFF, 1/2 ON | The communication address is 3 | |
Switches 5-4/1-2 OFF, 3 ON | The communication address is 4 | |
Switches 5-4/2 OFF, 3/1 ON | The communication address is 5 | |
Switches 5-4/1 OFF, 3/2 ON | The communication address is 6 | |
Switches 5-4 OFF, 3/2/1 ON | The communication address is 7 | |
Switches 5/3-1 OFF, 4 ON | The communication address is 8 | |
Omit... | (Defined by 8421 code combination in hexadecimal) | |
Switches 5-1 ON | The communication address is 31 |
Specification
Digital input/output | |
Input type | Passive node (dry contact) @withstand voltage ≥24VDC |
Active node (wet contact) | |
Counting pulse frequency | 1 to 40kHz Higher frequency range can be customized (Counting function needs to be customized) |
Relay output | 32 channels of relay outputs (NO contact, contact capacity AC250V*5A/DC30V*5A) |
Communication | |
RS485 interface | Connect up to 32 terminals (256 terminals for the enhanced version) |
Transmission distance: 1200 meters | |
± 15KV ESD protection | |
RS232 interface | RS232 serial port is usually equipped (Crossover cable is required when using RS232) |
Transmission distance: 10 meters | |
± 15KV ESD protection | |
RS485/232 | 7 communication rates and 6 formats are optional (MODBUS protocol 06 func. definition table for details) |
CAN interface | Parameters can be customized |
TCP IP network port | Max. transmission distance: 100 meters |
10/100Mbps | |
MDI/MDIX crossover directly and automatically switch | |
TCP Server/TCP Client/UDP Server/UDP Client working modes and port parameters can be freely set | |
Communication protocol | Standard Modbus-RTU protocol |
Standard Modbus-TCP protocol | |
CAN interface protocol | |
Other parameters | |
Isolation withstand voltage | 1500V DC |
Max. power consumption | <17W |
Auxiliary power supply | 24V/1A DC(21-26V), 12V/2A DC(10-15V) |
Operating temperature | -20℃~+60℃ |
Installation | Rail or screw mounting |
Models
ZH-YX3232-14N | 32 channels of switch input 32 channels of relay output 24V power supply RS485 interface |
ZH-YX3232-34N | 32 channels of switch input 32 channels of relay output 24V power supply Network interface |
ZH-YX3232-12N | 32 channels of switch input 32 channels of relay output 12V power supply RS485 interface |
ZH-YX3232-34N | 32 channels of switch input 32 channels of relay output 12V power supply Network interface |