KPM 73 Multifunction Meter

KPM 73 Multifunction Meter with accurate measurement of power parameters, bi-directional four-quadrant energy measurement, statistics, recording functions, using advanced ARM processor and digital signal processing technology.


Features

  • Measure over 30 kinds of basic electricity such as phase/line voltage, three-phase current, zero sequence voltage, zero sequence current, active power, reactive power, apparent power, active energy, reactive energy, power factor, frequency

  • Measure and display the average power factor of the last three months and accurately grasp the amount of monthly reactive energy consumption

  • Class 0.5S 4 quadrant power statistics and multi-rate statistics

  • Demand statistics and record the maximum value, minimum value Working hours, load time statistics

  • Time recording function, can record 100 event

  • Support up to 51st harmonic calculation, total harmonic distortion rate calculation, unbalance rate, current K factor calculation

  • Standard 1-way Rs485 communication interface, Modbus-RTU protocol, Optional Profibus-DP Communication module.

  • Optional 4-way passive digital input Optional 4-way relay output

  • Optional 1-way 4-20mA analog output

  • 1 road passive optical coupler collector active pulse output Optional 1-way PT100 temperature input

  • 256 points / cycle voltage, current sampling, to ensure measurement accuracy

  • FSTN large screen LCD, bright LED back light uniform display, in the bright light and large viewing angle environment to obtain a good visual effect

 

Application

  • All power parameter measurement;

  • Energy measurement and electrical fire monitor and control;

  • Replacing the three-phase power meter, three phase electricity transmitter;

  • Transformers, generators, capacitors and electric motors distributed detection;

  • Medium and low pressure systems;

  • SCADA, EMS, DCS integrators.

 

Specification

Working power sourceOperating VoltageAC 85-270V/DC 80-300V
Rated power consumption< 3VA
Input voltageRated voltage57.7/100V,220/380V,380V/660V Need to customize
Sill value5V
Overload capacity1.2 times rated voltage allowed, continuous work; 2 times the rated voltage allowed 1second
Power consumption<0.5VA/phase(rated)
Measurement rangePhase voltage(LN):50~270VAC, line voltage(LL):90~470VAC
Input currentFrequency range45~65Hz
Rated currentDefault 5A,Input range 1-6A;Optional 1A,Input range 1-1.2A
Sill value5A Configuration,5mA ;1A Configuration,0.8mA
Overload capacity1.2 times rated current allowed, continuous work; 20 times the rated current allowed 1 second
Power consumption<0.75VA/phase(Rated current 5A);<0.25VA/phase(Rated current 1A)
Input outputSwitch value input4-way passive main line contact DI input, internal supply DC24V power source
Relay output4-way DO output, Contact capacity 250VAC/5A,30VDC/5A
Analog outputOutput range 4~20mA,overload allows 1.2times
Temperature inputMeasure range 0℃~100℃
Power quality monitorHarmonic measurementVoltage/current 2~51st harmonic distortion rate total harmonic distortion rate.
Harmonic distortion ratePhase voltage, line voltage
Imbalance rateVoltage. current
Measurement accuracyVoltage±0.2%(0.01V)
Current±0.2%(0.01A)
Active power±0.5%(0.1W)
Reactive power±2.0%(0.1kvar)
Active energy±0.5%(0.1kWh)
Reactive energy±2.0%(0.1kvarh)
Power factor±0.5%(0.001)
Frequency±0.02Hz(0.01Hz)
Temperature±1℃(1℃)
CommunicationCommunication interfaceRS485,Profibus-V1,Photoelectric isolation interface
Communication protocol

ModbusRTU,1200~38400bps;

Probibus-DP,9600~12Mbps

Electrical

insulation

Power frequency withstand voltageAC2kV/min~1mA Input-output-power source
Insulation resistance>50MΩ
Impact voltage5kV Peak ,1.2/50us
Working environmentOperating temperature-25℃ ~ +70℃
Relative humidity5%~95% No condensation
Storage temperature-30℃ ~ +75℃
AltitudeNo more than 4000m
Electromagnetic CompatibilitySurge (impact) immunityIEC61000-4-5,Level4

Electrical fast burst

immunity

IEC61000-4-4,Level4

Electrostatic discharge

immunity

IEC61000-4-2,Level4

Power frequency magnetic

field immunity

IEC61000-4-8,Level4


Send Inquiry to This Supplier