KPM31 Single Phase Digital Energy Meter
- Product Details
- Company Profile
KPM31 Single Phase Digital Energy Meter
KPM31 Single Phase Digital Energy Meteris designed with advanced microprocessor and digital signal processing technology. It integrates comprehensive single-phase power measurement, display, energy accumulation, and network communication.
lt has strong anti-interference ability and can still work stably in situations with severe electromagnetic interference.
Features
Measurement of voltage, bidirectional current, active power, reactive power, apparent power, power factor, frequency, active energy, reactive energy.
Multi-rate energy statistics, up to 8 time slots per day, 4 tariffs.
12-month historical power statistics function.
Rated current 5-63A.
1 passive optical coupler collector active pulse outputs.
Default Modbus communication through RS485 interface. Optional Wi-Fi communication.
LCD display a variety of power parameters and information.
Built-in clock and maintenance-free battery,permanently data saving after power off.
Large-capacity magnetic retention relay, load on-off control.
Application
All power parameter measurement;
Energy measurement and electrical fire monitor and control;
Replacing the three-phase power meter, three phase electricity transmitter;
Transformers, generators, capacitors and electric motors distributed detection;
Medium and low pressure systems;
SCADA, EMS, DCS integrators.
Specification
KPM31Multifunction meter-Technical parameters | ||
Input voltage | Rated voltage | AC 110V/220V |
Overall power consumption | <5VA/ | |
Frequency range | 45~65Hz | |
Input current | Rated current | 1,5(6)A,10(60)A,20(100)A |
Frequency range | 45~65Hz | |
Measurement accuracy | Voltage | ±0.2%(0.01V) |
Current | ±0.2%(0.01A) | |
Active power | ±0.5%(0.1W) | |
Reactive power | ±2.0%(0.1kvar) | |
Active energy | ±0.5%(0.1kWh) | |
Reactive energy | ±2.0%(0.1kvarh) | |
Power factor | ±0.5%(0.001) | |
Frequency | ±0.02Hz(0.01Hz) | |
Clock | Clock accuracy | <0.5S/D |
Communication | Communication interface | RS485,Photoelectric isolation interface |
Electrical insulation | Communication protocol | Modbus-RTU,1200~38400bps |
Power frequency withstand voltage | AC2kV/min~1mA Input-output-power source (GB/T 13729) | |
Insulation resistance | >50MΩ (GB/T 13729) | |
Impact voltage | 5kV(Peak),1.2/50us (GB/T 13729) | |
Working environment | Operating temperature | -25℃ ~ +70℃ |
Relative humidity | 5%~95% No condensation | |
Storage temperature | -30℃ ~ +75℃ | |
Altitude | No more than 4000m | |
Electromagnetic Compatibility | Surge (impact) immunity | GB/T 17626.5-2008,Level4 |
Electrical fast burst immunity | GB/T 17626.4-2008,Level4 | |
Electrostatic discharge immunity | GB/T 17626.2-2006,Level4 | |
Power frequency magnetic field immunity | GB/T 17626.8-2006,Level4 |