ZJS-102 DC System Insulation Monitoring for detecting DC leakage current with RS485 comm.
ZJS-102 DC System Insulation Monitoring for detecting DC leakage current with RS485 comm.
ZJS-102 DC System Insulation Monitoring for detecting DC leakage current with RS485 comm.
ZJS-102 DC System Insulation Monitoring for detecting DC leakage current with RS485 comm.

ZJS-102 DC System Insulation Monitoring for detecting DC leakage current with RS485 comm.

Manufacturer

  • Product Details
  • Company Profile

ZJS-102 DC System Insulation Monitoring for detecting DC leakage current with RS485 comm.

Description


The DC system is the most important component of a high voltage industrial/utility substation. It supplies the energy to manage the protective devices and high voltage components and allows electrical faults to be safely isolated. Most high voltage substations house owns either a sealed or flooded cell battery bank.

 

Due to the complexity and dynamics of DC systems, DC ground faults caused by positive grounding or negative grounding are often difficult to be located. At the same time, due to the wide applications of intelligent relays and integrated automation systems, higher requirements are placed on the accuracy and safety of the DC system grounding monitoring device.

 

ZJS-102 DC System Insulation Monitor provides real-time online monitoring of insulation status of DC bus and branch circuit. It combined the balance bridge detection with unbalanced bridge detection two modes, to avoid the interference of distributed capacitance in the system, and also ZJS-102 can display the leakage current of each circuit in real time.

 

Features

l  Real-time monitoring DC system voltage, pole to ground voltage and alarm

l  Real-time monitoring system insulation and alarm

l  Detection DC system distributed capacitance

l  DC system branch circuit insulation detect and classification pre-warning

l  DC system branch circuit leakage current detection and diagnosis

l  Balance bridge and unbalanced bridge detection combined detecting insulation condition.

l  Auto record of instantaneous grounding event and wave capture

l  Support configuring battery bank as a special branch, and provide leakage locating for battery bank

l  History recording and export to USB memory

l  5.0-inch touch screen display parameters and configuration

l  Front panel with 6 individual alert LEDs

l  Rear panel have 7 DO ports for important alarm info to PLC

l  Singe device supports 240 branch circuit monitor

l  Current sensors support hot-swapping and sensor failure detection

l  Provide multiple devices in parallel mode to expand detect circuit quantities

l  Subs slave device support hot-swapping and automatic identification

l  RS485 and Ethernet (optional) communication port

 

 

 Application

l  DC speed regulating motor

l  Solar power generation and other fields

l  DC or AC/DC main circuits

l  UPS systems, battery systems.

l  IT systems with high leakage capacitances

l  DC charging stations for electric vehicles.

 

Specification

Monitoring   range of insulation resistance to ground

Earth alarm

0~50K

Pre-warning

50~300K

Working   voltage range

Positive pole to ground

0~300V

Negative pole to ground

0~300V

System voltage

0~300V

AC injection voltage

0~280V

Busbar-II system voltage (DC cross   detect)

0~300V

Battery bank insulation fault location   error

±1 cell

Alarm   history record

Record list quantities

2000 lists

Each record alarm list volume

≤32 branches

Real-time   leakage current measurement

Screen display resolution

0.01mA

Current sensor range

10mA, 20mA, 50mA, 100mA optional

Each ZJS-102 port detect current volume

≤240 branches

Each ZJS-CU collector unit connected   current sensor

≤8

Instant   event record

Capture sampling ratio

1KHz, 500Hz, 250Hz, 125Hz configurable

Record quantities

2000

Waveforms for each instantaneous event

8

Others

Passive digital output

7

Fault alarm indicator

6

Distributed capacitance range of the   system

0~200uF

Voltage monitoring error

≤0.5%

Communication interface

RS485, Ethernet

System vo0ltage balance compensation   bridge

40K, 60K, 120K

Optional AUX

220VAC

 