MENU
China Chamber of Commerce

Overseas Economic and Trade Zones

Confirm
Cancel
x

Ok
x
Sign into your account
Member ID or Email
Join Free
GYDCG-UBC1 DC charging pile  dc insulation monitor with RS485,used for DC EV charger
GYDCG-UBC1 DC charging pile  dc insulation monitor with RS485,used for DC EV charger
GYDCG-UBC1 DC charging pile  dc insulation monitor with RS485,used for DC EV charger
GYDCG-UBC1 DC charging pile  dc insulation monitor with RS485,used for DC EV charger

GYDCG-UBC1 DC charging pile dc insulation monitor with RS485,used for DC EV charger

Manufacturer

  • Product Details
  • Company Profile

GYDCG-UBC1 DC charging pile dc insulation monitor with RS485,used for DC EV charger

Description


GYDCG-UBC1 series products are insulation monitoring devices that integrate various high-voltage monitoring functions, including DC-to-ground insulation resistance monitoring (real-time monitoring of positive and Pile special function), voltage reverse connection alarm, DC capacitor discharge (special function for DC charging pile) and other safety monitoring functions. It can be used in various DC systems such as electric vehicle DC charging systems, photovoltaic systems, energy storage systems, and DC grids.\


This product has the insulation monitoring start-stop function. After the insulation monitoring is started, it can monitor the insulation resistance of the positive and negative electrodes to the ground in real time. The monitoring results are not affected by DC voltage fluctuations, and are not affected by the symmetry of the positive and negative insulation resistance.

 

Features

l  Wider power supply range, compatible with 12V and 24V input

l  The insulation resistance monitoring can be realized in the range of DC 100V~1000V;

l  High accuracy and speed—obtain results within 2.5 seconds after turning on;

l  Realize insulation resistance monitoring when the positive and negative poles to ground capacitance are less than 3uF;

l  Convenient, communication parameters can be set by dial switch

 

Application

l  EV DC charging system

l  Photovoltaic system

l  Energy storage system

l  DC power grid and other DC systems under 1000V

 

Specification

Model

DCG-UBC1

Detect channels

Single channel

DC voltage range

0~1000V

Power supply

9~30VDC

Insulation resistance range

1KΩ~10MΩ (100V~1000V)

Insulation monitoring accuracy

≤3KΩ+10% (100-300V)

≤3KΩ+5% (300-1000V)

Measurement accuracy

≤2V+0.3%

Storage temperature

-40°C ~ 125°C

Operating temperature& humidity

-40°C   ~ 70°C, 85%

Off-line pressure test

<2mA

Communication

RS485   Modbus

Installation type

Din   Rail mount

Dimensions

49mm*   98mm*62mm

 