TRE2-50/2 Frame.50 ELCB Bimetal Type, Korea Design
TRE2-50/2 Frame.50 ELCB Bimetal Type, Korea Design
TRE2-50/2 Frame.50 ELCB Bimetal Type, Korea Design
TRE2-50/2 Frame.50 ELCB Bimetal Type, Korea Design
TRE2-50/2 Frame.50 ELCB Bimetal Type, Korea Design
TRE2-50/2 Frame.50 ELCB Bimetal Type, Korea Design

TRE2-50/2 Frame.50 ELCB Bimetal Type, Korea Design

Member Details

ZHEJIANG QIANNA ELECTRIC CO.,LTD.

China

Manufacturer

  • Product Details
  • Company Profile

TRE series circuit breaker and auxiliaries comply with the following international standard: 1.IEC/EN 60947-1 Low-voltage switchgear and controlgear-part 1: General rules; 2.IEC/EN 60947-2 Low-voltage switchgear and controlgear-part 2: Circuit breakers; TRE series ELCB(Standard use environment for TRE series ELCB) 1. Ambient temperature: Within the range of -5oC--+40oC(However, the average for the duration of 24 hours must not exceed 35oC); 2. Altitude: 2000m or less 3. Installation class: III 4. The magnetic field near the instalation site should not be more than five times the earth magnetic field in any direction. 5. Pollution: II Classification: According to the poles: 2-poles, 3-poles According to the rated current: Fix type According to the trip action time: Fix type According to the rated residual current: Fix type

TRE2-50 series ELCB

Standard:
TRE series circuit breaker and auxiliaries comply with the following international standard:
1.IEC/EN 60947-1
Low-voltage switchgear and controlgear-part 1: General rules;
2.IEC/EN 60947-2
Low-voltage switchgear and controlgear-part 2: Circuit breakers;

TRE series ELCB(Standard use environment for TRE series ELCB)
1. Ambient temperature: Within the range of -5oC--+40oC(However, the average for the duration of 24 hours must not exceed 35oC);
2. Altitude: 2000m or less
3. Installation class: III
4. The magnetic field near the instalation site should not be more than five times the earth magnetic field in any direction.
5. Pollution: II

Classification:
According to the poles:                                          2-poles, 3-poles
According to the rated current:                               Fix type
According to the trip action time:                            Fix type
According to the rated residual current:                 Fix type


Technical data table:

Model (AF)50AF

Product type
TRE2-50/2TRE2-50/3

Number of poles
23

Rated current (A)
In5, 1015, 20, 30, 40, 505, 1015, 20, 30, 40, 50

Rated voltage(V)
Ue220/415220/415

Rated Insulated voltage (V),  50/60Hz
Ui500500

Rated impulse voltage(kV)
Uimp66

Rated residual current(mA)
3030

Action time(sec)
<0.03 sec<0.03 sec

Ultimate breaking capability(kA)
GB 14048.2, IEC/EN 60947-2
Icu220V415V220V415V220V415V220V415V
52.510552.5105
lcs=%×lcu75%75%75%75%

Dimensions (mm)

downLoadImg.jpg

a5075
b9898
c6060
d8080
Weight (kg)0.310.41