1.Scope
This specification provides the technical requirements of alkaline manganese dioxide battery(LR6).The requirements and size should satisfy or above GB/T8897.1 and GB /T8897.2 if there is not any other detail requirements.
1.1Reference Standards
GB/T8897.1 (IEC60086-1,MOD)(Primary Battery Part 1:General)
GB/T8897.2 (IEC60086-2,MOD)(Primary Battery Part2:Size and Technical requirements)
GB8897.5 (IEC 60086-5,IDT)(Primary Battery Part5:Safety of batteries with aqueous electrolyte)
1.2Environmental Protection Standard
The battery meets the standard of EU battery directives 2006/66/EC.
2.Chemical system, Voltage and Designation
Chemical system:Zn-MnO2(KOH),without Hg & Cr
Nominal Voltage: 1.5V
Designation : IEC:LR6 ANSI: AA JIS:AM-3 Others:24A,E91
Operating Temp Range Spec of -20℃ to +60℃
3.Battery Size
Battery meets the picture standard
3.1 Inspection Tool
Using vernier calipers which precision is up 0.02mm. to avoid short-circuit, should paste on one insulation material on one end of the vernier calipers.
3.2 Acceptance Method
Using GB2828.1-2003 sampling program, special sampling S-3, acceptance quality limitation: AQL=1.0
4.Weight and discharging capacity
Battery weight about:22.0g
Discharging capacity:2200mAh(Loading43Ω,4h/day,20±2℃ RH60±15%,End-point Voltage0.9V)
5.Open circuit voltage, loading voltage and short-circuit current
Project | Open circuit Voltage(V) | Loading Voltage(V) | Short-circuit Voltage(A) | Sampling Voltage |
In 2 months | 1.60 | 1.45 | 7.00 | GB2828.1-2003 One Sampling, special sampling S-4,AQL=1.0 |
12 months storage in room temperature | 1.56 | 1.40 | 6.00 | |
Inspection Condition | Loading 3.9Ω, loading time 0.3s,temp:20±2℃ |
6.Discharging Ability
Discharging Temp:20±2℃ | |||||
Condition | GB/T8897.2-2008 | Shortest Average Discharging Time | |||
Load | Discharging Way | End-point Voltage | 2 months new battery | 12 months storage battery | |
43Ω | 4h/d | 0.9 V | 65h | 85h | 78h |
3.9Ω | 1h/d | 0.8 V | 4.5h | 6.5h | 6h |
24Ω | 15s/min,8h/d | 1.0 V | 31h | 40h | 36h |
3.9Ω | 24h/d | 0.9 V | / | 340min | 310min |
10Ω | 24h/d | 0.9 V | / | 17.5h | 16h |
Accordance of shortest discharging time
1)Testing 9 batteries of each discharging way;
2)The result of the average discharging time from each discharging standard shall be equal to or more than the average minimum time requirement; no more than one battery has a service output less than 80% of the specified requirement;
3)The result of the average discharging time from each discharging standard shall be equal to or more than the average minimum time requirement, if one battery has a service output less than 80% of the specified requirement then take another 9 pieces to test again。This lot of batteries are qualified if the result meets the NO.2 provision. If not qualified then will not test again.
7.Anti-leakage ability
Project | Condition | Requirements | Qualified |
Over Discharging | Continuous discharging 48h in 20±2℃,humidity 60±15%,load 10Ω condition. | No leakage by visual inspection | N=9 |
High-temp storage | Storing in 60±2℃, relative humidity 90% condition for 20 days. | N=30 |
8.Safety Requirements
Project | Condition | Requirements | Qualified Standard |
External Short-circuit | Using wire to connect positive and negative pole in 20±2℃ for 24h. | No Explosion | N=5 |
Improper Equipment | 4 batteries in series connection, one of them is in reverse connection. | Leakage happened on the reversed battery or the shell temp reduce to room temp | N=4×5 |
9.Signs
The following signs are on the battery body:
1.Model:LR6/AA
2.Manufacturer and brand:Daily-max
3.Battery Poles:“+”and“-”
4.Expiry date or manufacturing date
5.Warnings.
10. Cautions for using
1.This battery can’t be charged, leakage and explosion may happen when charging.
2.Make sure the battery is in correct position as + and -.
3.Short-circuit, heating, disposing of into fire or disassembling of battery is prohibited.
4.Battery can not be forced discharged, which leads to excess gassing and may result in bulging, leakage and de-crimping of cap.
5.New batteries and used ones can not be used at the same time. It is recommended to use the same brand when replacing batteries.
6.The battery should be taken out from the device which will not be used for a long time.
7.Exhausted battery should be taken out from the device.
8.Welding batteries are prohibited or it will cause damage.
9.The batteries should be kept from children, if swallowed, contact a doctor immediately.
11.Normal Package
Each 2,3 or 4 batteries in a shrink package,60 pieces in one inner box,12 boxes in one carton.
12.Storage and Expiry
1.Batteries should be put in cool, dry and with air-flowing places
2.The batteries should not be exposed in sunshine or in raining places.
3.Do not mix the batteries which without labels
4.Storing in 20℃±2℃, 60%±15%RH condition. The storage time is 3 years.
13. Nominal discharging curve
Discharging condition:20℃±2℃,RH60±15%
With the progress of product technology, technical parameters, the specification will be updated too, please contact to stand for latest specification.