MENU
China Chamber of Commerce

Overseas Economic and Trade Zones

Confirm
Cancel
x

Ok
x
Sign into your account
Member ID or Email
Join Free
DDZY217(S9-6)Single Phase Smart Energy Meter with Interchangeable Module and KEMA certific
DDZY217(S9-6)Single Phase Smart Energy Meter with Interchangeable Module and KEMA certific

DDZY217(S9-6)Single Phase Smart Energy Meter with Interchangeable Module and KEMA certific

Manufacturer

  • Product Details
  • Company Profile

DDZY217 ( S9-6 ) Single Phase Smart Energy Meter with Interchangeable Module can measure the import and the export active energy , and is with TOU and step tariff functions , and can be with PLC or RF module for communication , and can be controlled to disconnect or reconnect the load remotely .

 

Genaral introduction:

DDZY217 ( S9-6 ) Single Phase Smart Energy Meter with Interchangeable Module can measure the import and the export active energy , and is with TOU and step tariff functions , and can be with PLC or RF module for communication , and can be controlled to disconnect or reconnect the load remotely .

Main functions:

1. Data Snapshot: It supports freezing which includes daily freezing hourly freezing, occasional freezing, immediate freezing

2. Event logs: It can separatel record latest 10 times events, such as power outage, programming, time correction, meter cover open,disconnection/ re-connection, reset of events, reset of meter etc.

3. Display and indication: It adopts a large screen LCD with abundant graphics and hint text. The displayed contents can be scrolled automatically or by button, and the displayed items can be configured as per the requirements. It is with backlight. Meter can be read during power outage

Technical specifications:

Items                                                                         Contents

Standards                                                 IEC62052-11;IEC62053-21

Accuracy                                                      Active: Class 1                  

Protocol                                                       DL/T 645-2007                

Reference voltage                                   120V/220V/230V/240V                          

Current                                             Curent transformer connection: 1.5(6)A. Direct connection :10(40)A,10(60)A,20(80)A,10(100)A 

Reference frequency                                             50/60Hz                        

Power consumption                                             <1.5W, 6VA              

Operation voltage range                                      0.8Un~1.2Un                     

Limited operation voltage range                          0.7Un~1.3Un  

Operation temperature                                       -25℃~+60℃             

Limited operation temperature                          -40℃+70℃

RTC deviation                                                         ≤0.5s/d

Life time                                                                15 years

Size                                                       160mm(L)x112mm(W)x71mm(H)

Net weight                                                         About 0.6kg