MENU
China Chamber of Commerce

Overseas Economic and Trade Zones

Confirm
Cancel
x

Ok
x
Sign into your account
Member ID or Email
Join Free
temperature thermocouple tip
temperature thermocouple tip
temperature thermocouple tip
temperature thermocouple tip
temperature thermocouple tip
temperature thermocouple tip

temperature thermocouple tip

Manufacturer

  • Product Details
  • Company Profile

temperature thermocouple tip

  • 1.  Purpose and Working Principle of Disposable Thermocouple: 

Used for measuring the temperature of molten steel and high-temperature molten metal, this kind of thermocouple is disposable. Based on the thermoelectric effect of metals, it works according to the temperature differences between its two sides.

 

  • 2.  Product Specifications and Performance Comparisons:

Name

Model

Type

Tolerance

Recommended Temperature Range

Max Temperature

Response Time

Platinum-30% Rhodium/Platinum-6% Rhodium thermocouple 

KB-602/604

B

±3℃

1500-1700℃

1800℃

4~6s

Platinum-10% Rhodium/Platinum thermocouple

KS-602/604

S

±3℃

1500-1700℃

1800℃

4~6s

Platinum-13% Rhodium/Platinum thermocouple

KR-602/604

R

±3℃

1500-1700℃

1800℃

4~6s

Tungsten 30%/ tungsten-rhenium 25%

KW-602/604

W

±5℃

1500-1700℃

1800℃

4~6s

 

  • 3.  Structure

Disposable immersion thermocouple is mainly composed of temperature measuring probe and a big paper tube. Positive wire and negative wire of the temperature measuring probe are welded to an extension wire embedded in a support bracket covered by a small paper tube. The thermo wires are supported and protected by quartz tube. The temperature measuring probe is covered by a cap to protect from dregs. All the components are put into a thermocouple tip and are bonded by fire-resistant filler into a whole. Therefore, the kind of thermocouple is disposable.

 

  • 4.  Usage

1, To select the appropriate length of protective paper tube and thermocouple lance according to the object and scope of the measurement

2, Attach the disposable thermocouple to the thermocouple lance, make the pointer of the secondary instrument (or digital display) back to zero. Begin to measure.  

3, It is recommended to insert the disposable thermocouple into the molten steel at the depth of 300-400mm. Do not touch the furnace wall or scum. Bring up the thermocouple lance immediately after the secondary instrument get results. The soak time of disposable thermocouple in molten steel should be less than 6 seconds, otherwise the lance may be burned out.

4, Change the used thermocouple into a new one, and pause for a few minutes to get ready for the next measurement. 

 

  • 5.  Transport and Storage

Be careful when assembling and removing the parts. Keep dry in the transportational process. The products should be put into cases and stored at warehouses where the relative humidity is less than 80%. Keep the air flowing. The air should not contain harmful gases which may corrode the products. 

 

Send Inquiry to This Supplier

  • Title
  • From*
  • toChangLiHua
  • Message*
  • Minimum Order Quantity*
  • Unit
  • Verification Code*