Miniature Circuit Breaker 1P 6A to 63A
- Product Details
- Company Profile
Miniature Circuit Breaker 1P 6A to 63A
Miniature Circuit Breaker 1P 6A to 63A
Name: Miniature Circuit Breaker 1P 6A to 63A
Series: J65 series
Pole: 1P 2P 3P 4P
Rated Voltage: 230V/400V~
Rated current: 6A – 63A
Breaking Capacity: 6KA
Mechanical life: 20000 times
Electrical life: 10000 times
MOQ: 5000 poles
Product Details:
Our miniature circuit breaker 1P 6A to 63A, with its perfect quality to satisfy customer’s requirement, you can see the inside of our circuit breaker :
This miniature circuit breaker 1P 6A to 63A belongs to our new range J65 series, we have improved its function which is much better
Like: we have 5 rivets to be fixed on side, which make our miniature circuit breaker 1P 6A to 63A to be stronger.
Complementary:
Network frequency: 50/60Hz
System Voltage: 240V between Phase and Neutral AC 50/60Hz 60V DC
Magnetic tripping limit: 8.5 x In +/- 20% AC
Rated insulation voltage: 500V AC50/60Hz conforming to EN/IEC 60947-2
Raged impulse withstand voltage: 6KV conforming to EN/IEC 60947-2
Local signaling : ON/OFF indication
Mounting mode: Clip-on
Mounting support: DIN rail
Our Advantages
1. Factory price & high quality
2. Fast delivery & good packing
3. Different colors are available for your choice
4. Experienced staff and QC team work
5. Experienced in processing, designing , quality control ,after service. etc
6. 36 years’ experience of manufacture and marketing .
7. One-stop solution for projects to save your money and time.
Shipping:
Load Container via Leliu Port to Nansha Port Guangzhou or Shekou port Shenzhen
Provide Service: EXW, FOB, Door to Door
Accept Order :FCL ,LCL
Provide Shipping method : By Air or By Sea or by Express
We always choose the most economical and reliable shipping company to make sure you can receive the goods in time .The tracking number will be provided once the shipment is completed .
What is an MCB?
A miniature circuit breaker (MCB) automatically switches off electrical circuit during an abnormal condition of the network means in overload condition as well as faulty condition.
Nowadays we use an MCB in low voltage electrical network instead of a fuse. The fuse may not sense it but the miniature circuit breaker does it in a more reliable way. MCB is much more sensitive to overcurrent than fuse.
Handling an MCB is electrically safer than a fuse. Quick restoration of supply is possible in case of a fuse as because fuses must be re-wirable or replaced for restoring the supply. Restoration is easily possible by just switching it ON. Let’s look at the working of the miniature circuit breaker.