Input: 220VAC, 230VAC, 240VAC, 100VAC, 110VAC, 120VAC±25% Output: 220VAC, 230VAC, 240VAC, 100VAC, 110VAC, 120VAC Battery Voltage: 36VDC Payment terms: T/T or L/C or Western Union Lead time: 15~18 days Warranty: 1 year
HTS Series three phase input and single phase output online ups
HTS series Brief
HTS series intelligent pure sine wave online UPS, the capacity can be from (10KVA~20KVA)three phase in and single phase out) , HTS series congregates the essence of Baykee advanced technology and the world’s most advanced 16 -bit high speed CPU control technology and 40KHZ high frequency technology.The UPS has small volume, light weight. high efficiency,zero transfer time and pure sine wave output etc features.This series UPS adopts the most advanced interface information operation technology, the user can see the UPS operation status directly from the LCD. With digital self-detecting and protection function, the long distance monitoring can reach the international advanced level.It is the power guard for your Commercial server, PC server and peripheral, communication and internet appliance, PC and the other nicety electronic appliance.
Feature:
1. Digital Design
Adopted DSP control technology and digital design topology, C UPS can be operated and maintained more conveniently.
2. A Real Green-environmental Protection Power.
The commercial power input factor correction technique is used .Under the Normal mode, UPS achieves real energy-saving by inputting harmonic less than 10% and frequency power factor above 99%.
3. Direct Current Cold Start Function
When battery input voltage in the range of normal voltage. By pressing the ON button ,
UPS can start up normally.
4.Alarm High-low Battery Input Voltage Protection Function
UPS alarms in case of the battery input voltage too high or too low. As the battery continuously go up or down out of the normal range, UPS will alarm and stop input or transfer to bypass mode to ensure the battery life and protect user appliance
5.Communication and Monitoring Function
Equipped with standard RS232 interface and intelligent slot. The UPS Operating and electrical parameters can be monitored through standard RS232. Through intelligent slot status inter face he intelligent control can be flexibly configured according to different applications to users, for instance ,stem node, network, monitoring, text message
6.Output High- Low Voltage Protection
When UPS output is greater than the output over-voltage protection point or less than the output low-voltage protection point, it will shut off inverter output to bypass and automatically alarm .After all the fault removed, users can restart the machine normally.
7.Output Short Circuit Protection
When the Inverter output overloaded and short circuit ,UPS will stop output and alarm and blink continuously. After the troubleshooting, it can restart normally.
8. Overloaded Protection Function 6KVA to 10KVA
When Overload out of ranged load in certain time ,UPS will turn off the inverter and switch to Bypass output by alarming .After the load back to normal, UPS automatically transfer back to inverter output.
9. Over-temperature Protection
When the temperature is over high or the fan work abnormally, it will lead the main radiator temperature out of over temperature protection. At that point UPS will alarm and switch to Bypass output .Until the temperature recover normally, UPS will automatically switch to inverter output
10. Intelligent Fan Speed Control Function
According to load capability and environmental temperature, the fan speed adjustment can reduce the noise and prolong the service life.
Parameters:
MODEL | HTS-10KH | HTS-15KH | HTS-20KH | |
Capacity | 10kVA | 15kVA | 20kVA | |
Power Watt | 8000W | 1200W | 1600W | |
Phase | Three Phase Input / Single Phase Output | |||
INPUT | ||||
Voltage Range | Low Voltag eConversion | 275VAC-475VAC | ||
Low Voltage Recovery | ||||
High Voltage Conversion | ||||
High Voltage Recovery | ||||
Frequency Range | 46-54Hz or 56-64Hz | |||
Power Factor | 0.95 | |||
OUTPUT | ||||
Output Voltage | 220VAC ± 1% ( Battery Mode ) | |||
Frequency Range | 47~53Hz or 57Hz~63Hz ( Synchronized Range ), 50/60Hz±0.3Hz ( Battery Mode ) | |||
Output Power Factor | 0.8 | |||
Crest Factor | 3:1 | |||
Harmonic Distortion | <2% ( Linear Load ) | |||
Transfer Time | AC-DC: 0ms, Inverter to Bypass: 4ms ( Typical ) | |||
Waveform | Pure Sine Wave | |||
Overload Capacity | 105-125%, Transfer to Bypass after 1min, 125-135%, Transfer to Bypass after 30s and disconnect output after 1min, >135%, Transfer to Bypass after 0.5s | |||
EFFICIENCY | ||||
AC Mode | 89% | |||
Battery Mode | 88% | |||
BATTERY | ||||
DC Voltage | 192VDC | 192VDC | 192VDC | |
Standard Model | Inbuilt Battery Capacity | External Battery | ||
Quantity | 16 | 16 | 16 | |
Charge Time | Depending on External Battery | |||
Max. Charge Current | 1.0A | |||
Charge Voltage | 219.2VDC±1% | |||
Long time Model | Capacity | Depending on External Battery | ||
Quantity | Depending on External Battery | |||
Max. Charge Current | 1.0A/2.0A/4.0A/6.0A | |||
Charge Voltage | 219.2VDC±1% | |||
DISPLAY | ||||
LCD or LED | Load, Battery Capacity, AC Mains Mode, Battery Mode, Bypass Mode, Fault Indicator | |||
ALARM VOICE | ||||
Battery Mode | Ring one time per 4 seconds | |||
Battery Low Capacity | Ring one time per 1 seconds | |||
Overload | ring one time per 0.5 second | |||
Faults | continue to ring | |||
PHYSICAL PERFORMANCE | ||||
Standard Model | Tower Size ( D*W*H) mm | |||
Weight ( Kg ) | ||||
Long time Model | Tower Size (D*W*H) mm | 248*520*616 | ||
Weight ( Kg ) | 28.5 | 36.5 | 36.5 | |
Rack-mounted Size ( D*W*H ) mm | ||||
ENVIRONMENT | ||||
Humidity | 20-90% RH @ 0-40℃ ( Non-condensing ) | |||
Noise | <58dB @ 1M | |||
CONTROL MANAGEMENT | ||||
Smart RS232 ( Optional USB ) | Support Windows2000/2003/XP/Vista/2008/7, Linux, Unix | |||
Optional SNMP | Support SNMP card for Remote Control |