high-frequency infrared carbon sulfur analyzer
- Product Details
- Company Profile
CS-9000 series high-frequency infrared carbon sulfur analyzer, consisting of automatic constant pressure oxygen supply, high frequency induction furnace, infrared detectors, computer, electronic scales and printers, it is a fast, accurate, reliable automatic analyzer. Analysis process as follows: When the sample combustion in a high frequency furnace, element of carbon & sulfur it contains is oxidized to CO2, CO and SO2, oxygen-vector will be sent into infrared detector, generates an electrical signal via the infrared detector enlarge evacuation computer data processing, final results of the analysis like percentage content of carbon and sulfur can be printed out.
CS-9000 series high-frequency infrared carbon sulfur analyzer
CS-9000 series high-frequency infrared carbon sulfur analyzer, consisting of automatic constant pressure oxygen supply, high frequency induction furnace, infrared detectors, computer, electronic scales and printers, it is a fast, accurate, reliable automatic analyzer. Analysis process as follows: When the sample combustion in a high frequency furnace, element of carbon & sulfur it contains is oxidized to CO2, CO and SO2, oxygen-vector will be sent into infrared detector, generates an electrical signal via the infrared detector enlarge evacuation computer data processing, final results of the analysis like percentage content of carbon and sulfur can be printed out.
CS-9000 series high-frequency infrared carbon sulfur analyzer induction furnace with a reverse sweep with automatic dust removal function can automatically remove dust, ensure that the analysis results are accurate and reproducible, reduce manual cleaning, improve efficiency, de-dust power comes from the combustion exhaust gas, truly saving and environmental protection.
Common Parameters
Analysis time: 30 ~ 50s
Measuring principle: High-frequency combustion infrared absorption method
Analysis gas: pure oxygen 99.5%
Power gas: Nitrogen or compressed air without water
Power: 220V ±5%
Weight: 85 kg
Dimensions: 565×465×720 mm
CS-9001 High-frequency Infrared Carbon Sulfur Analyzer
CS9001 series of high-precision high-frequency infrared carbon and sulfur analyzer, adopt high-frequency combustion system and infrared analysis system; Integrated structure, with four sets of infrared detection system.
Specifications:
Measuring range: Standard sample weight
Carbon element:
C1: 0.001 ~ 50% expandable up to 100%
C2: 0.00001 ~ 0.5%
Sulfur:
S1: 0.1 ~ 60% expandable up to 100% (optional)
S2: 0.00001 ~ 5%
Sensitivity: 0.1ppm
Repeatability:
Carbon R S D ≦ 0.5%
Sulfur RSD ≦ 1.5%
Accuracy:
Carbon: better than ISO 9556 standard
Sulfur: Better than ISO 4935 standard
CS-9002 High-frequency Infrared Carbon Sulfur Analyzer
CS9002 series of high-precision high-frequency infrared carbon and sulfur analyzer, adopt high-frequency combustion system and infrared analysis system; Integrated structure, with two sets of infrared detection system.
Specifications:
Measuring range: Standard sample weight
Carbon element:
C1: 0.0001 ~ 20% expandable up to 100%
C2: 0.00001 ~ 0.5% (Optional)
Sulfur:
S1: 0.1 ~ 60% expandable up to 100% (optional)
S2: 0.00001 ~ 5%
Sensitivity: 0.1ppm
Repeatability:
Carbon R S D ≦ 0.4%
Sulfur RSD ≦ 1.0%
Accuracy:
Carbon: better than ISO 9556 standard
Sulfur: Better than ISO 4935 standard
Optional
Detection module system
Double sulfur detector Double carbon detector CO detector Carbon & sulfur detector
Processing system
CS1000 Processing system is specially designed processing device to use high frequency infrared carbon sulfur analyzer accurately analyze minerals, geology, clay and etc containing crystalline water or organic sample, it used U.S. Patent water molecules separating techniques to separate water molecules from mixed gas combustion which generated in combustion, and drain water molecules through built circulation system, so as to ensure accurate detection of CO2 and SO2 are not impact by moisture; Compact structure & long service life, either pre-integrated inside the instrument can also be installed as an independently accessories.
Control Software
Multiple preset curve, system can be stored a maximum of 80 carbon & sulfur curve.
User setting curve is supported. Multi authority control, can be divided according to grade different privileges.
Temperature, flow rate, peak width, carbon monoxide compensation, system is stable and reliable.
Analysis results automatically recorded in the database, support query, print and mathematical statistics, data can be output as Excel sheet.
Experimental results playback function.
Support for single-point or multi-point calibration function.
Self-test and alarm functions can be set in software.