Gas chromatographic analyzer
Gas chromatographic analyzer

Gas chromatographic analyzer

Member Details

Changsha Friend Experimental Analysis Instrument Co., Ltd

Changsha,Hunan,China

Manufacturer,Scientific Researcher

  • Product Details
  • Company Profile

high performance

 Scope of application

  Determination of water (drink) volatile organic compounds, blood alcohol content detection, detection of indoor air pollutants (TVOC), liquor flavor component analysis, transformer oil analysis, testing, high purity gas analysis of residual solvents in pharmaceuticals, medical devices residues Determination of ethylene oxide. 

     The main use of the chromatograph unit: liquor factory, other wineries, petrochemical, gas liquefaction plant, the coal industry, environmental testing, inspection station, Forensic Center, the public security system, food plants, quality inspection departments, water plants, pharmaceutical plants, detection of pesticide plants, gas plants, chemical plants, packaging plants, paint factory, honey factory, chemical engineering colleges and other trace ingredients are needed to gas chromatography, liquid chromatography

                                          

Function characteristics

1, the gas chromatograph using a large LCD Chinese display, intuitive operation, the instrument has a self-diagnosis, power protection, file storage and call, eight bands temperature-programmed functions. 

2, the gas chromatograph with a separate vertical heated capillary inlet system, minimizing the impact on the column compartment vaporization chamber, improving the adaptability of various syringes. Makeup capillary system has an adjustable diaphragm, cleaning adjustable, adjustable split ratio. 

3, the new FID has high sensitivity and can be easily and ion collector nozzle loading and unloading. Has six independent temperature regions, the vaporization chamber, detector and amplifier are used in modular design, easy installation and replacement simple. 

4, column oven capacity, can also install a capillary and packed column, with three separate injector, according to the analysis requirements, installation of gas, liquid inlet, 0.53 wide caliber can easily complete the installation of a capillary column; according to the analysis requirements may also increase the six-way injection valve, reformer devices, and to achieve the detector in series and parallel work.

 

Technical parameters

Temperature Indicators 

Temperature Zone: Column box, injector, detector 

Temperature range: room temperature5 ~450 (increments of1

Temperature accuracy: better than ±0.1  

Temperature program: Eight-order rate0.1 ~40 / min (increments of0.1

please leave your contact details when send inquiry!

 

Send Inquiry to This Supplier

  • Title
  • From*
  • to
  • Message*
  • Minimum Order Quantity*
  • Unit
  • Verification Code*