IEC884-1/GB2099.1 Needle Flame Test Chamber
- Product Details
- Company Profile
Needle Flame Test Chamber is used to test the resistance of fire caused by an interior fault such as leakage current in cable & wire
is used to test the resistance of fire caused by an interior fault such as leakage current in cable & wire and the like. It meets the requirements of Chinese GB4706.1, GB5169.5, and IEC60695-2-2 and IEC61347-1 standards.
Application
Electrician & electron product
Components and accessories of household appliances
Features
* All stainless steel and brass constructions.
* Burner can be ignited automatically.
* Temperature and test time display by digital meters.
* A big window in the door makes your viewing more convenient.
Technical parameter
Power source: Depending on country/region of installation
The interior capacity: 0.5 m3
Inside diameter of burner: 0.5 +- 0.1 mm
Outside diameter of burner: Less than 0.9mm
Length of burner: No less than 35mm
Flame height: 12 +-1 mm(adjustable)
Flame period: 0~99m99s
Temperature rise period: 23.5s+-1.0s(from 100+-20C to 700+-30C)
Gas: Butane (at least 95.0 percent pure, provided by clients)
Exterior dimensions: 1200× 1100× 1400 mm(W× D× H)
Weight: 105KG
Testing Standards
IEC884-1, GB2099.1, VDE, IEC335, GB4706.1, GB5169.5, UL1694
Needle Flame Test ChamberNeedle Flame Test Chamber
http://www.lab-testequipment.com/Needle-Flame-Test-Chamber.html