DSHX-3 Three-Component Borehole Magnetometer
- Product Details
- Company Profile
Applications and Feature: ?Used for magnetic exploration. Suitable for using in drilling with diameter greater than ?6mm for measurement of horizontal component X, Y and vertical component Z in magnetic field.And also be used as high-precision inclino
·
Verify ground magnetic abnormality, and determine
the nature of abnormality.
Verify ground magnetic abnormality, and determine
the nature of abnormality.
·
Combined with ground magnetic survey for
three-dimensional interpretation.
Combined with ground magnetic survey for
three-dimensional interpretation.
·
High-precision measurement of deviation azimuth
and inclination.
High-precision measurement of deviation azimuth
and inclination.
·
Searching of magnetic ore associated ore deposits.
Searching of magnetic ore associated ore deposits.
·
Instruct the drilling arrangement, and guide the
drilling.
Instruct the drilling arrangement, and guide the
drilling.
·
Determine the depth and direction of blind ore.
Determine the depth and direction of blind ore.
·
Determination of the occurrence of ore bodies.
Determination of the occurrence of ore bodies.
Technical
Specifications:
Specifications:
·
Measuring Range: -99999nT~+99999nT
Measuring Range: -99999nT~+99999nT
·
Difference of readings at the opposite
orientation for X, Y magneto sensors ≤400nT
Difference of readings at the opposite
orientation for X, Y magneto sensors ≤400nT
·
Difference of readings at the opposite
orientation for Z magneto sensor ≤ 300nT
Difference of readings at the opposite
orientation for Z magneto sensor ≤ 300nT
·
Inclination Measuring Range: 0~45°, Error:
smaller than 0.2°
Inclination Measuring Range: 0~45°, Error:
smaller than 0.2°
·
Azimuth Measuring Range: 0~360°, Error: smaller
than 2° (inclination ≥3°)
Azimuth Measuring Range: 0~360°, Error: smaller
than 2° (inclination ≥3°)
·
Linearity ≤2
Linearity ≤2
·
Digital Output, Update Rate ≥ 3 times / sec
Digital Output, Update Rate ≥ 3 times / sec
·
Probe Outline Dimension: φ40×1400mm
Probe Outline Dimension: φ40×1400mm
Measured Well Depth ≤ 2000m
·
Probe Pressure-Proof ≤ 150kg/cm2
Probe Pressure-Proof ≤ 150kg/cm2
·
Dedicated Cable: 4-core Armed Cable
Dedicated Cable: 4-core Armed Cable
·
Instrument Working Power Supply: DC12V/200mA
Instrument Working Power Supply: DC12V/200mA
Working Environment: Temperature: 0~70°;
Humidity: 90% (40℃)
·
Master Instrument Outline Dimension: 305×200×228
mm
Master Instrument Outline Dimension: 305×200×228
mm