DSHB-1 Portable Engineering Logging System
- Product Details
- Company Profile
DSHB-1 Portable Engineering Logging System
A-S3521
Sound Wave Probes
Sound Wave Probes
Technical
Parameters
Parameters
1. Single-transmission and
double-receiving non-orientation survey
2. Measurement range: 1000~7000m/s
3. Transmission period: 106ms
4. Transmission sound wave frequency: 20KHz±5KHz
5. Scale precision: 1%
6. Source distance: 0.5M; space distance: 0.2M
7. Frame size: ф50*1650mm
8. Weight: 5Kg
9. Endured pressure: 5Mpa
10. Working temperature: -10℃~70℃
double-receiving non-orientation survey
2. Measurement range: 1000~7000m/s
3. Transmission period: 106ms
4. Transmission sound wave frequency: 20KHz±5KHz
5. Scale precision: 1%
6. Source distance: 0.5M; space distance: 0.2M
7. Frame size: ф50*1650mm
8. Weight: 5Kg
9. Endured pressure: 5Mpa
10. Working temperature: -10℃~70℃
Function
:
:
Rock nature partition and determine rock
layer porosity, air layer judgment and fissure detection; can determine rock
aquifer saturation.
layer porosity, air layer judgment and fissure detection; can determine rock
aquifer saturation.
A-JD-1A
Electrode Serial Probes
Electrode Serial Probes
Applications: penetrated rock layer partition and
determine invaded zone resistivity.
determine invaded zone resistivity.
determine rock layer thickness, stratum
water resistivity, estimate mud content
water resistivity, estimate mud content
Functions:
potential
resistivity, grads resistivity, measured parameters, and natural potential
resistivity, grads resistivity, measured parameters, and natural potential
Technical
Parameters
Parameters
1. Resistivity measurement range: 0~10KΩm
2. Measurement sensitivity: 0.04Ωm
3. Scale precision error: <5%
4. Outside frame size: φ38*950mm
5. Weight: 2Kg
6. Endured pressure: ≥5Mpa
7. Working temperature: -10℃~70℃
2. Measurement sensitivity: 0.04Ωm
3. Scale precision error: <5%
4. Outside frame size: φ38*950mm
5. Weight: 2Kg
6. Endured pressure: ≥5Mpa
7. Working temperature: -10℃~70℃
A-WX3521
Well Temperature, 3-Direction Combination Probes
Well Temperature, 3-Direction Combination Probes
Technical
Parameters
Parameters
1. Temperature sensitivity (16 digits
A/D) sampling: superior to 0.2℃/bit
A/D) sampling: superior to 0.2℃/bit
2 Well temperature measurement range:
-10℃~+150℃
3. Temperature feeling time: <3s
4. Well temperature stability error: <1%
5. Well temperature scale error: <±0.5℃
6. 3-direction resistivity measurement range: 0~10KΩm(adjustable)
7. Resistivity sensitivity (16 digits A/D) sampling: <0.1Ωm
8. Resistivity stability error: <5%
9. Resistivity measurement precision error: <5%
10. Digital transmission: 8bit
11. Frame size: φ40*1415mm
12. Weight: 3.4Kg
13. Endured pressure: ≥5Mpa
14. Working temperature: -10℃~60℃
Functions:
-10℃~+150℃
3. Temperature feeling time: <3s
4. Well temperature stability error: <1%
5. Well temperature scale error: <±0.5℃
6. 3-direction resistivity measurement range: 0~10KΩm(adjustable)
7. Resistivity sensitivity (16 digits A/D) sampling: <0.1Ωm
8. Resistivity stability error: <5%
9. Resistivity measurement precision error: <5%
10. Digital transmission: 8bit
11. Frame size: φ40*1415mm
12. Weight: 3.4Kg
13. Endured pressure: ≥5Mpa
14. Working temperature: -10℃~60℃
Functions:
the parameter of well temperature is
geothermal survey to explore geothermal
resource, determine mineral layer location in hydrogeology and sediment study, 3-direction
resistivity is fit for rock high resistivity thin layer combination or
alternation layers with complex structure.
geothermal survey to explore geothermal
resource, determine mineral layer location in hydrogeology and sediment study, 3-direction
resistivity is fit for rock high resistivity thin layer combination or
alternation layers with complex structure.