本法规旨在规定通信设施中隔震器的技术规范。
1.增加了通信设施用隔震器的技术标准(附表2第4条)
-楼板反应谱标准(0.5~33.3Hz),通过接受美国土木工程师学会的非结构元件振动表测试标准,反映国内建筑的地震特性。
-提供抗震隔离器的安装条件、性能验证方法、判断条件等。
2.电信设施抗震性能分析和验证目标的扩展(附表2的2.b.5-6)
-它已经放宽,允许对电力设备和辅助设备(整流器除外)进行分析和验证。
拟议通过日期:2021年12月
拟议生效日期:2022年7月或更晚
英文原文:
This regulation is to specify technical specifications of seismic isolator in the telecommunication facilities.
1. Added technical standards for seismic isolators for telecommunication facilities (4 of Schedule 2)
- Floor response spectrum standards (0.5~33.3 Hz) reflecting the earthquake characteristics of domestic buildings by accepting the non-structural element vibration table test standards of the American Society of Civil Engineers.
- Provision of installation conditions for seismic isolators, performance verification methods, judgment conditions, etc.
2. Expansion of targets for analysis and verification of seismic performance of telecommunication facilities (2.b.5-6 of Schedule 2)
- It has been relaxed to allow analysis and verification of power equipment and ancillary equipment except for rectifiers.
Proposed date of adoption: December 2021
Proposed date of entry into force: July 2022 or later